Specifications:

General

Operating System
Network Appliance™ Data ONTAP™ 6.5.1 software
Standard Software Features
Integrated automatic RAID manager, Snapshot™, Fast Boot, telnet, e-mail alerts, NIS, DNS, SNMP, FilerView®, NDMP
Network Protocol Support
NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft® CIFS, DAFS, HTTP 1.0, HTTP 1.1 virtual hosts
SAN Protocol Support
Fibre Channel Protocol (FCP) for SCSI; fabric-attached and direct-attached; iSCSI
Hardware Features
Full-duplex 10/100Base-T Ethernet onboard, diagnostic LED/LCD, Remote Management Card standard, redundant hot-plug cooling fans, redundant hot-plug power supplies, Compact Flash, 19" rack-mount enclosure, optional 220V 42U 19" system cabinet
Default/Min./Max. RAID Group Sizes
Default: 7 data + 1 parity/Min.: 1 data + 1 parity/Max.: 27 data + 1 parity
Disk Shelves Supported (Fibre Channel)
FC71, FC81, FC9, DS14, DS14mk2 FC
Disk Drive Capacities Supported
92/182/36/72/144GB

System Specifications

Max. Raw Capacity
12TB
Max. Number of Disk Drives
336
Max. Number of FC Loops
4
Max. Drives per FC Loop
56 or 843
File Systems (Minimum/Maximum)
1/9
Volumes and RAID Groups (min./max.) Min. of 1 RAID Group per Volume
2/224
Max. Volume Size
6TB
ECC Memory
4GB
Nonvolatile Memory
512MB
PCI-X Expansion Slots
10
Optional Network Connectivity (total)
10 max.
Quad Gigabit Ethernet (Cu)
3 max.
Dual Gigabit Ethernet (Cu or optical)
8 max.
Gigabit Ethernet (Cu or optical)
10 max.
DAFS—(GbE VI/IP)
8 max.
Dual Fibre Channel for Host Attach - SAN
8 max.
Dual FC Disk Adapters
8 max.
Single FC Disk Adapters (Cu for legacy shelves)
4 max.
Clustered Failover–Capable
Standard
Dual FC, Single FC, or LVD SCSI Adapters for Tape
4 max.

System Environment

AC Power/Current
100 to 240VAC, 6.6A (typical)/24A (max.) @ 100VAC
Thermal Rating
2,250 Btu/hr
Weight
214 lb (97 kg)
Height
52.8 cm (20.8")
Width
19" IEC rack-compliant (17", 43.2 cm)
Depth
22" (56 cm), 25" (63.5 cm) with cable management bracket
Operating Temperature and Relative Humidity
10° C to 40° C (50° F to 104° F); less than 2,100 m (less than 7,000') elevation; 10° C to 35° C (50° F to 95° F) less than 3,000 m (less than 10,000') elevation; 20% to 80% relative humidity, noncondensing
Nonoperating Temperature and Relative Humidity
-20° C to 65° C (-4° F to 149° F); 8% to 95% relative humidity, noncondensing, in original container
Operating Acoustic Noise
less than 52 dBA @ 1 m, less than 66 dBA @ 1 m high temp/degraded mode
Min. Cabinet Clearances
1.5" (3.8 cm) for bezel, 3" (7.6 cm) for cable radius
Min. Service Clearances
9" (23 cm) front; 30" (76 cm) rear

Storage Subsystem Specifications - SCSI Disk Shelf 12 (SDS12)

Host Interface
PCI based ultra-2 LVD SCSI
Disk Drive Storage Shelf
SCSI Disk Shelf 12—up to 12 LVD SCSI drives (6 or 12 drive configurations)
Cooling Fans/Power Supplies
Redundant fans; hot-pluggable redundant power supplies

Storage Subsystem Environment - SCSI Disk Shelf 12

AC Power/Maximum Current
115-230 VAC/20 A at 115 V
Operating Environment
10° C to 35° C (50° F to 95° F) 8% to 80% relative humidity, non-condensing
Non-operating Environment
-40° C to 650° C (-40° F to 149° F) 85 to 80% relative humidity, non-condensing
Thermal Rating
1160 BTU/hr.
Operating Acoustic Noise
45 dBA @ 23° C